4SC950005

  OPTICAL REFECTOR FOR COFFEE 0-18% BX

The refrector is a tool that measures the percentage of dissolved substances in the sample. That substace is refracted by a light.For the espresso the correct value is between 8 and 12%, while for filter preparations is between 1.2 and 1.45%.
 

9V0761

  PORTABLE TOTAL CHLORINE CHECKER - LOW SCALE (0-500ppb)

Easier to use and more accurate than chemical test kitsEPA approved DPD method. Accuracy ± 5 ppb ± 5% of reading. Resolution 1 ppb. Automatic shutdown.Dedicated to a single parameterDesigned to work with powder reagents and 10ml cuvettes. Checker® HC weighs only 64g and fits comfortably in the palm of your hand or pocket. It is ideal for quick and precise field analyzes. A single button allows all operations to be carried out. Works with a single AAA battery. Ideal for: Water quality, education, disinfection, environmental controls.Powder reagent kit code 9V076125Standard code calibration cuvettes code 9V076111
 
novita
 

9V076111

  STANDARD CUVETTE TOTAL CHLORINE - LOW SCALE

Standard calibration cuvettes provide a simple solution for the validation of Checker HC® for Ultra Low Low Chlorine, in a range from 0 to 500 ppb.
 

9V076125

  POWDER REAGENT KIT (25 TEST)

Suitable fro 9V0761 codeThey are replacement reagents for Checker® HC for Ultra Low Scale Total Chlorine. These high quality reagents are marked, for traceability, with the lot number and expiration date on each sachet.
 

9V103107

  COFFEE HYDROMETER

The coffee hydrometer is used to know the quantity of coffee in water.
 

9V70004

  CALIBRATION SOLUTION 20ML PH 4.01 -SACHET

It is a standard pH 4.01 calibration solution produced in accordance with ISO 3696 / BS3978 standards using pure salts, deionized water, certified scales and Class A glass materials in a temperature controlled environment with certified thermometers. The values shown have an accuracy of +/- 0.01 pH at 25 °C and refer to the NIST (Standard Reference Materials - SRMs) standards.• Ideal for users who do not calibrate the instrument frequently• Ideal for use in the field• Each sachet contains fresh solution• The package protects the solution from UV rays that could alter the value of the buffer.The solution contains no dyes which can stain the reference cell of a pH electrode.Accuracy pH ± 0.01 pHPH value @ 25 ° C 4.01
 

9V70007

  CALIBRATION SOLUTION 20ML PH 7.01 - SACHET

It is a standard pH 7.01 calibration solution produced in accordance with ISO 3696 / BS3978 standards using pure salts, deionized water, certified scales and Class A glass materials in a temperature controlled environment with certified thermometers. The values shown have an accuracy of +/- 0.01 pH at 25 °C and refer to the NIST (Standard Reference Materials - SRMs) standards.• Ideal for users who do not calibrate the instrument frequently• Ideal for use in the field• Each sachet contains fresh solution• The package protects the solution from UV rays that could alter the value of the buffer.The solution contains no dyes which can stain the reference cell of a pH electrode.Accuracy pH ± 0.01 pHPH value @ 25 ° C 7.01
 

9V70010

  CALIBRATION SOLUTION 20ML PH 10.01 -SACHET

It is a standard pH 10.01 calibration solution produced in accordance with ISO 3696 / BS3978 standards using pure salts, deionized water, certified scales and Class A glass materials in a temperature controlled environment with certified thermometers. The values shown have an accuracy of +/- 0.01 pH at 25 ° C and refer to the NIST (Standard Reference Materials - SRMs) standards.• Ideal for users who do not calibrate the instrument frequently• Ideal for use in the field• Each sachet contains fresh solution• The package protects the solution from UV rays that could alter the value of the buffer.The solution contains no dyes which can stain the reference cell of a pH electrode.Accuracy pH ± 0.01 pHPH value @ 25 ° C 10.01
 

9V70031

  CALIBRATION SOLUTION 20ML CONDUCIVITY 1413uS/cm -SACHET

It is a standard conductivity solution at 1413 μS / cm referable to NIST standards with a conductivity meter calibrated with NIST 2202 SRM ("Standard Reference Material") potassium chloride, in accordance with ISO 3696 / BS3978 standards. The sachets are made with a material that keeps the solution fresh and prepared using deionized water, Class A glass materials, certified scales and thermometers.
 

9V70033

  CONDUCTIVITY STANDARD 84uS/CM - 230ml

It is a standard solution of conductivity at 84 µS / cm. Conductivity solutions have the batch number and expiration date indicated on the label and are supplied in an airtight bottle which guarantees the quality of the solution. These solutions have been formulated to last up to 5 years from the production date, if the bottle is not opened.
 
novita
 

9V96810

  DIGITAL COFFEE REFRACTOMETER 0-26% BRIX WITH HM COFFEE APP

Brix is a measure of solid substances dissolved in a liquid. A Brix degree (symbol Bx) corresponds to 1 part of solid substance (dry weight) in 99 parts of solution. For example, a 25 ° Bx solution contains 25 grams of solid substances in 75 grams of total liquid.Units of measurement: Brix, TDS, TemperatureMeasurement range: Brix: 0,00% - 26,00%TDS: 0,00% - 23,00%Temperature: 0,0 ° C - 70,0 °CResolution: Brix: 0,01%TDS: 0,01%Temperature: 0,1 °CAccuracy: Brix: ± 0,20% TDS: ± 0,20%Temperature: ± 1,0 °CTemperature compensation: ATC (10 °C - 60 °C)Backlight: Automatic brightness control (20 seconds)Auto-off: 2 minutesMeasurement time: 5 seconds approxSample volume: 0,5 mL approxOperating temperature: 10 °C - 40 °CBatteries: 2 x 1,5V AAA alkaline batteriesDimensions: 58x36x122 mmWeight: 150g (including batteries and protective covers)
 

9V96811

  DIGITAL REFRACTOMETER 0-50% BX SUITABLE TO ESPRESSO AND AMERICAN COFFEE

Sugar Content Range 0 to 50% BrixSugar Content Resolution 0.1% BrixSugar Content Accuracy (@25ºC/77ºF)     ±0.2% BrixTemperature Range 0 to 80°C (32 to 176°F)Temperature Resolution 0.1°C (0.1°F)Temperature Accuracy ±0.3 °C (±0.5 °F)Temperature Compensation automatic between 10 and 40°C (50 to 104°F)Measurement Time: approximately 1.5 secondsMinimum Sample Volume 100 μL (to cover prism totally)Light Source yellow LEDSample Cell s.steel ring and flint glass prismAuto-off after three minutes of inactivityEnclosure Rating IP65Battery Type / Life 9V / approximately 5000 readingsDimensions / Weight 192 x 102 x 67 mm (7.6x4.01x2.6”) /420 g(14.8 oz.)
 

9V98100

  POCKET CHECKER® PLUS PH TESTER

pH Range 0.00 to 14.00 pHpH Resolution 0.01 pHpH Accuracy ±0.2 pHCalibration: automatic, one or two points with three standard buffers available (pH 4.01, 7.01 and 10.01)Battery Type/Life 1.5V CR2032 (1) / approximately 1000 hours of continuous useElectrode/Probe HI1271 pH electrode with screw type connector (included)Environment 0 to 50°C (32 to 122°F); RH max 95%Dimensions 50 x 174 x 21 mm (2 x 6.8 x 0.9”)Weight 50 g (1.8 oz.)
 

9V98101

  EC DIGITAL CONDUCTIVE (FS 1999US/CM, RES +/-2%FS)

Conversion 20μS = 1f°EC Range 0 to 1999 μS/cmEC Resolution 1 μS/cmEC Accuracy ±2% F.S.Calibration: automatic at 1413 μS/cmProbe Connection: directDimensions 180 x 50 x 25 mm (7.1 x 2.0 x 1.0”)Weight 50 g (1.8 oz)Temperature Compensation: automatic from 0 to 60°C (32 to 140°F), β = 2%/°CBattery Type / Life 1.5V (2) / approximately 200 hours of continuous use; auto-off after 5 minutes of non-useEnvironment 0 to 50°C (32 to 122°F); RH max 95%
 

9V98308

  PURE WATER CONDUCTIVITY TESTER (FS 99,9US/CM)

It is a portable, robust and precise conductivity tester in pure water. It is equipped with a graphite electrode which reduces the effects of polarization and an integrated temperature probe. Manual one-point calibration is possible.Integrated temperature sensor.Very low EC scale from 0.0 to 99.9 μS / cm.Manual calibration at a single point.
 
novita